Mechanical & Connector Fit5 min readUpdated 2026-11-20

Coroflex® Outer Diameters, Cable Gland Fit & Minimum Bending Radius Reference

Exact Coroflex® core and outer sheath diameters with factory minus-tolerances for IP68 EMC cable glands, TE/Amphenol/Rosenberger HV connector seals, and verified static vs dynamic bend radii.

Coroflex outer diameter mmFHLR2GCB2G cable gland sizeEV HV cable bending radiusCoroflex 9-2611 OD tableCoroflex 9-2641 multi-core diameter

Minimum Bending Radius: Shielded vs Unshielded Rules

Exceeding the minimum bend radius on a braided HV cable kinks the tinned-copper screen, opens optical shield gaps, and stresses silicone wall thickness. Always apply the exact OEM rule for your series — do not mix unshielded and shielded multipliers:

  • Coroflex 9-2611 (Single-Core Shielded FHLR2GCB2G): minimum 3 × outer diameter (static installation) / minimum 6 × outer diameter (dynamic installation).
  • Coroflex 9-2641 (Multi-Core Shielded FHLR2GCB2G): minimum 3 × outer diameter (static installation) / minimum 6 × outer diameter (dynamic installation).
  • Coroflex 9-2652 (Single-Core Unshielded FHL2G): minimum 2 × outer diameter (static installation) / minimum 4 × outer diameter (dynamic installation).

Single-Core Outer Diameters & Tolerances (9-2611 & 9-2652)

Coroflex® dimensions use strict minus-only tolerances (for example, 14.40 (-0.6) mm means an actual OD window of 13.80 mm to 14.40 mm). When selecting IP68 EMC cable glands or silicone connector rear seals, verify that BOTH the maximum nominal OD and the minimum tolerance bound sit inside the gland's clamping range.

Verified Single-Core Diameters — Coroflex® 9-2611 (Shielded) & 9-2652 (Unshielded)

Verified Single-Core Diameters — Coroflex® 9-2611 (Shielded) & 9-2652 (Unshielded)
Size9-2611 Core OD9-2611 Outer Sheath OD9-2652 Outer Sheath OD
2.5 mm²On request (CoC)On request (CoC)3.60 (-0.3) mm
4 mm²3.70 (-0.3) mm5.80 (-0.5) mm4.40 (-0.4) mm
6 mm²4.30 (-0.3) mm6.50 (-0.5) mm5.00 (-0.4) mm
10 mm²6.00 (-0.6) mm8.80 (-0.6) mm6.50 (-0.6) mm
16 mm²7.20 (-0.6) mm10.20 (-0.6) mm8.30 (-0.6) mm
25 mm²8.80 (-0.6) mm12.20 (-0.6) mm10.00 (-0.6) mm
35 mm²10.50 (-0.7) mm14.40 (-0.6) mm11.00 (-0.7) mm
50 mm²12.20 (-0.7) mm15.80 (-0.6) mm13.20 (-0.8) mm
70 mm²14.40 (-1.4) mm18.20 (-0.8) mm15.10 (-0.8) mm
95 mm²17.20 (-1.4) mm20.90 (-0.8) mm17.40 (-1.0) mm

Multi-Core Outer Diameters & Weights (Coroflex 9-2641)

Because Coroflex 9-2641 uses an extruded circular inner filling layer, its outer sheath maintains high concentric roundness across 2-, 3-, 4-, and 5-core variants for reliable circular gland compression:

Verified Multi-Core Diameters & Nominal Weights — Coroflex® 9-2641

Verified Multi-Core Diameters & Nominal Weights — Coroflex® 9-2641
ConfigurationSoliconn SKUIndividual Core ODOuter Sheath ODOEM Nominal Weight
2-Core × 2.5 mm²SC-CF92641-2C-2P5MM3.00 (-0.3) mm9.90 (-0.6) mmapprox. 160 g/m
2-Core × 4 mm²SC-CF92641-2C-4MM3.70 (-0.3) mm11.30 (-0.6) mmapprox. 220 g/m
2-Core × 6 mm²SC-CF92641-2C-6MM4.30 (-0.3) mm12.80 (-0.6) mmapprox. 290 g/m
3-Core × 2.5 mm²SC-CF92641-3C-2P5MM3.00 (-0.3) mm10.40 (-0.6) mmapprox. 186 g/m
3-Core × 4 mm²SC-CF92641-3C-4MM3.70 (-0.3) mm12.10 (-0.6) mmapprox. 268 g/m
3-Core × 6 mm²SC-CF92641-3C-6MM4.30 (-0.3) mm14.10 (-0.6) mmapprox. 390 g/m
4-Core × 4 mm²SC-CF92641-4C-4MM3.70 (-0.3) mm13.30 (-0.6) mmapprox. 330 g/m
4-Core × 6 mm²SC-CF92641-4C-6MM4.30 (-0.3) mm15.10 (-0.6) mmapprox. 453 g/m
5-Core × 6 mm²SC-CF92641-5C-6MM4.30 (-0.3) mm16.30 (-0.6) mmapprox. 540 g/m

Frequently Asked Questions

How do I read Coroflex minus-only diameter tolerances like 12.20 (-0.6) mm?

The stated nominal figure is the upper maximum outer diameter (12.20 mm), and (-0.6) gives the lower limit (11.60 mm). Your cable gland or connector seal must clamp cleanly across the full 11.60–12.20 mm band.

Are Coroflex silicone outer sheaths talc-free for reliable IP68 sealing?

Yes. Coroflex 9-2611, 9-2652, and 9-2641 feature talc-free silicone rubber surfaces engineered for consistent elastomer sealing inside automotive HV connectors and EMC glands.

What is the minimum static bend radius for 35 mm² shielded Coroflex 9-2611?

With a nominal outer diameter of 14.40 mm and a 3 × OD static multiplier for shielded FHLR2GCB2G, the minimum static bending radius is approximately 43.2 mm (and 86.4 mm for dynamic routing at 6 × OD).

Continue Engineering Research

All Technical Guides
Need Cut-to-Length Stock or 500m+ Drum Pricing?

Browse all 29 UK-stocked Coroflex® HV SKUs or submit a bulk freight RFQ.