Cable Selection5 min readUpdated 2026-11-20

Coroflex® 9-2611 vs 9-2652 vs 9-2641: Shielded, Unshielded & Multi-Core EV HV Cables

Compare construction layers, EMC screening, LV 216-1/-2 compliance, rotary stripping, and minimum bending radii across all three Coroflex® +180 °C silicone high-voltage EV cable series.

Coroflex 9-2611Coroflex 9-2652Coroflex 9-2641FHLR2GCB2G vs FHL2Gshielded vs unshielded EV high voltage cable

Side-by-Side Coroflex® HV Series Architecture

All three Coroflex® high-voltage families manufactured by Coroplast Fritz Müller GmbH & Co. KG share flexible bare stranded E-Cu ETP1 copper conductors (DIN EN 13602), talc-free high-voltage orange (RAL 2003) silicone rubber insulation (2G), ISO 6722-1 Class E thermal endurance (-40 °C to +180 °C continuous for 3,000 h; +205 °C short-term for 240 h), and rated electrical withstand of 600 V AC / 1,000 V DC (8.0 kV spark test / 5.0 kV 5-minute test).

Selecting the right series comes down to EMC exposure, harness routing geometry, and whether you are feeding high-current traction phases or multi-conductor auxiliary subsystems.

Verified OEM Architecture Comparison — Coroflex® 9-2611, 9-2652 & 9-2641

Verified OEM Architecture Comparison — Coroflex® 9-2611, 9-2652 & 9-2641
SpecificationCoroflex 9-2611 (Single Shielded)Coroflex 9-2652 (Single Unshielded)Coroflex 9-2641 (Multi-Core Shielded)
DIN / Coroflex CodeFHLR2GCB2G (180HV SSC)FHL2G (180HV USC)FHLR2GCB2G (180HV SMC)
LV 216 SpecificationLV 216-2 Table A.2LV 216-1 Table A.1LV 216-2 Table A.5
Available Sizes1C × 2.5 to 95 mm² (10 SKUs)1C × 2.5 to 95 mm² (10 SKUs)2C–5C × 2.5 / 4 / 6 mm² (9 SKUs)
EMC ShieldingTinned Cu braid (min. 85% coverage) + ALU-PET foil (min. 20% overlap)Unshielded (enclosed packs & PDUs)Tinned Cu braid (min. 85% coverage) + ALU-PET foil (min. 20% overlap)
Min. Bend Radius (Static / Dynamic)3 × OD / 6 × OD2 × OD / 4 × OD3 × OD / 6 × OD
Primary EV Use CaseBattery-to-inverter, inverter-to-motor, external chassis DC busInside metallic battery packs, junction boxes & enclosed PDUsOn-board chargers (OBC), DC-DC converters, e-compressors, PTC heaters

When to Choose Shielded 9-2611 vs Unshielded 9-2652

High-frequency PWM switching from EV traction inverters generates intense electromagnetic interference that couples into nearby CAN bus, resolver, and low-voltage sensor harnesses. Any high-voltage run exiting a metallic enclosure along the vehicle chassis requires the 360° tinned-copper braid and aluminum/PET foil screen of Coroflex 9-2611 (FHLR2GCB2G) terminated into EMC HV connectors or shielded cable glands.

Inside a fully enclosed metal battery pack, power distribution unit (PDU), or stationary test cabinet where the enclosure itself provides Faraday shielding, Coroflex 9-2652 (FHL2G) removes the shield layer to cut cable outer diameter, weight, and bend radius down to 2 × OD static / 4 × OD dynamic — dramatically easing tight internal busbar-to-contactor routing.

Why Coroflex 9-2641 Simplifies Auxiliary HV Harness Processing

Auxiliary EV loads — including e-compressors, PTC coolant heaters, DC-DC converters, and 2- to 5-conductor on-board chargers (OBC) — typically draw moderate currents across 2.5 mm², 4.0 mm², or 6.0 mm² conductors. Routing multiple discrete single-core shielded cables consumes bulkhead glands and doubles EMC termination labor.

Coroflex 9-2641 bundles 2, 3, 4, or 5 color-coded silicone cores inside an extruded white circular modified-silicone inner filling layer beneath the braided screen and foil wrap. This high-roundness filling layer allows automated or manual rotary stripping tools to cut cleanly through the braided shield without nicking individual core insulation, eliminating hard-to-strip loose fillers and separating tapes.

Frequently Asked Questions

Can I use unshielded Coroflex 9-2652 outside a battery enclosure?

Unshielded FHL2G (9-2652) is engineered for use inside shielded enclosures such as metallic battery packs, PDUs, and test cabinets. External vehicle chassis runs subject to automotive EMC standards should use shielded FHLR2GCB2G (9-2611 single-core or 9-2641 multi-core).

Do Coroflex 9-2611 and 9-2641 share the same bending radius as 9-2652?

No. Per Coroflex official Technische Information sheets, shielded 9-2611 and 9-2641 specify a minimum bending radius of 3 × cable OD (static) and 6 × cable OD (dynamic), whereas unshielded 9-2652 allows a tighter 2 × cable OD (static) and 4 × cable OD (dynamic).

What is the white inner layer inside Coroflex 9-2641 multi-core cables?

It is an extruded circular modified-silicone filling layer over the twisted cores. It maintains tight cable roundness for reliable connector gland sealing and protects the underlying color-coded cores during rotary shield stripping.