Verified 20 °C Maximum Conductor & Screen DC Resistance
Ohmic heating (I²R) and DC bus voltage drop start with the conductor's verified maximum DC resistance at +20 °C. Note that multi-core Coroflex 9-2641 conductors have a slightly higher maximum DC resistance per cable meter (7.8 / 4.8 / 3.2 mΩ/m for 2.5 / 4 / 6 mm²) than single-core 9-2611 and 9-2652 (7.60 / 4.71 / 3.14 mΩ/m) due to the helical lay-up length of stranded multi-core assemblies.
Official Coroflex® Maximum DC Resistance at +20 °C (from Factory Datasheets)
| Cross-Section | Single-Core Conductor Max R (9-2611 / 9-2652) | 9-2611 Braided Screen Max R | Multi-Core 9-2641 Conductor Max R |
|---|---|---|---|
| 2.5 mm² | 7.60 mΩ/m | On request | 7.8 mΩ/m |
| 4.0 mm² | 4.71 mΩ/m | 13.8 mΩ/m | 4.8 mΩ/m |
| 6.0 mm² | 3.14 mΩ/m | 11.2 mΩ/m | 3.2 mΩ/m |
| 10 mm² | 1.82 mΩ/m | 9.1 mΩ/m | N/A (Single-core only) |
| 16 mm² | 1.16 mΩ/m | 7.6 mΩ/m | N/A (Single-core only) |
| 25 mm² | 0.743 mΩ/m | 4.4 mΩ/m | N/A (Single-core only) |
| 35 mm² | 0.527 mΩ/m | 3.8 mΩ/m | N/A (Single-core only) |
| 50 mm² | 0.368 mΩ/m | 3.7 mΩ/m | N/A (Single-core only) |
| 70 mm² | 0.259 mΩ/m | 2.7 mΩ/m | N/A (Single-core only) |
| 95 mm² | 0.196 mΩ/m | 1.9 mΩ/m | N/A (Single-core only) |
Why +180 °C Silicone Enables Smaller, Lighter Cross-Sections
Standard PVC or cross-linked XLPE automotive cables hit continuous insulation ceilings at +105 °C or +125 °C. Coroflex® 180HV silicone rubber (2G) is rated for continuous operation from -40 °C to +180 °C (3,000 h per ISO 6722-1 Class E) and short-term thermal ageing up to +205 °C (240 h). Note that legacy Coroplast T200 9-2652 series sheets cite up to +200 °C (3,000 h) / +225 °C (240 h), while all current Coroflex 180HV specifications standardize on +180 °C continuous.
In high-ambient engine bay, under-floor battery, or inverter compartments (+85 °C to +140 °C ambient), that extra thermal headroom allows engineers to choose an optimized copper cross-section (for example, 35 mm² or 50 mm² instead of oversized low-temp cables), directly reducing harness weight, packaging space, and copper cost.
Reading Official Coroflex® LV112-3 Current-Load Curves
Because continuous current capacity depends strongly on ambient temperature (+20 °C, +85 °C, +125 °C, and +140 °C), bundling factor, and short-term duty cycle, Coroflex® does not publish a single universal ampacity number. Instead, every factory Technische Information (TI) PDF includes dedicated LV112-3 heating curves plotting conductor temperature versus continuous DC current load.
Always verify your worst-case ambient temperature and continuous/peak current directly against the official OEM LV112-3 curve for your exact cross-section:
Frequently Asked Questions
Why does multi-core 9-2641 have slightly higher conductor DC resistance than 9-2611?
Because the individual insulated cores in a multi-core 9-2641 cable are helically twisted together, each conductor has a slightly longer physical path per meter of finished cable — raising the 20 °C limit from 4.71 to 4.8 mΩ/m (4 mm²) and 3.14 to 3.2 mΩ/m (6 mm²).
What temperature rating applies to Coroflex 9-2611, 9-2652, and 9-2641?
All three Coroflex 180HV series are rated for -40 °C to +180 °C continuous operation (3,000 hours, ISO 6722-1 Class E) with short-term ageing up to +205 °C (240 hours). Legacy Coroplast T200 9-2652 reference sheets note +200 °C (3,000 h) / +225 °C (240 h).
Where can I check exact continuous ampacity at +85 °C or +125 °C ambient?
Open the factory Coroflex Technische Information (TI) PDF for your target cross-section — each TI sheet includes official LV112-3 temperature-rise curves for +20 °C, +85 °C, +125 °C, and +140 °C ambient conditions.